Previous determinations

Determinations are made by MBIE on matters of doubt or dispute to do with building work. Rulings are legally binding, but only in relation to each case.

Previous determinations may provide some useful guidance for those faced with similar problems, but note that individual circumstances may vary.

You can also search for Determinations on Building CodeHub

Find a determination

Applying filters will narrow down your search results

Find a determination

Search results

377 Determinations match your query
Show detailed results

2022/008: Compliance of a timber retaining wall with Building Code clauses B1 Structure and E1 Surface Water that provide protection of other property

This determination considers whether building work to construct a new retaining wall close to the boundary between two properties complies with Building Code clauses B1 Structure and E1 Surface water that have the purpose of protecting other property.

About this document

2022/005: Compliance of building work with Building Code clauses B1 Structure and E1 Surface Water, that provide protection of other property

This determination considers whether building work to construct an extension to an existing deck, a new retaining wall, and other structures along a boundary between two properties, comply with Building Code Clauses B1 Structure and E1 Surface Water that provide for the protection of other property.

About this document

2022/003: Compliance of proposed alterations to a dwelling by way of Acceptable Solutions B1/AS1 and E2/AS3

This determination considers whether two items of proposed building work comply with the relevant Acceptable Solutions. Item 1 concerns reinforcing bars to reinforce a concrete floor slab and whether the proposal complies with Acceptable Solution B1/AS1 for Building Code Clause B1 Structure. Item 2 concerns the use of a damp-proof membrane as waterproofing for a 1060mm high retaining wall and whether the proposal complies with Acceptable Solution E2/AS3 for Building Code Clause E2 External Moisture.

About this document

2022/002: Regarding compliance of as-built timber retaining walls with the Building Code as it relates to the protection of other property

This determination considers whether the construction of timber retaining walls complies with Building Code clauses B1 Structure and F5 Construction and Demolition Hazards as they relate to the protection of other property.

About this document

2021/028: Regarding the decision to issue a code compliance certificate for building work to re-pile an existing house

This determination considers whether the authority were correct to issue a code compliance certificate for the building work to partially re-pile an existing house. The determination considers whether the building work can be considered as a minor variation.

About this document

2021/020: Regarding the refusal to issue a code compliance certificate for 23-year old alterations to a residential dwelling

This determination considers whether an authority was correct to refuse to issue a code compliance certificate for a building consent granted in 1998 under the former Building Act 1991. The determination will discuss the reasons given by the authority for the refusal, and how they relate to Building Code clauses B1 Structure, B2 Durability, E1 Surface Water, and E2 External Moisture that applied in 1998.

About this document

2021/008: Regarding the authority's decision to issue a code compliance certificate for a new dwelling

This determination considers whether an authority was correct to issue a code compliance certificate for a new dwelling. The determination considers whether the building is compliant, and whether the authority would have been aware of any non-compliance when issuing the code compliance certificate.

About this document

2021/007: Regarding the code compliance of a frameless glass balustrade on a house

This determination considers the code compliance of a frameless cantilevered glass balustrade. The balustrade panels comprise a laminate of two toughened-glass panes with a plastic interlayer. Concerns about compliance of the balustrade were raised when the interlayer did not prevent a panel from collapsing when the glass was broken.

About this document

2021/003: The refusal to issue a code compliance certificate for 20-year-old additions and alterations to a 50-year-old house

This determination considers an authority’s refusal to issue a code compliance certificate for 20-year-old additions and alterations due to concerns about compliance with the Building Code. The determination considers the authority’s reasons for refusal and whether those items identified by the authority are compliant with the Building Code.

About this document

2021/001: Regarding the refusal to grant a building consent for the conversion of part of a building from a carpark to a nightclub

This determination considers an authority’s decision not to grant building consent to a leaseholder for alterations to part of a building, based on the authority’s view that the seismic performance of the whole building was required to be upgraded. The determination discusses the requirement in section 115 for a building undergoing a change of use to comply, as nearly as is reasonably practicable, with the provisions of the Building Code relating to structural performance.

About this document

This information is published by the Ministry of Business, Innovation and Employment’s Chief Executive. It is a general guide only and, if used, does not relieve any person of the obligation to consider any matter to which the information relates according to the circumstances of the particular case. Expert advice may be required in specific circumstances. Where this information relates to assisting people: